Good Quality Infusion Pump in Hot Sales

Model NO.: MED-OIP-900
Net Weight: 2.2kg
Pump Type: Drip Type Infusion Pump
Pumping Way: Peristalic Fingers
Adjustable Drop Rate Range: 1~400 Drops/Min (Step: 1 Drop/Min)
Purge Rate: 800 Ml/H
Infusion Volume Range: 1 Ml~9999.9 Ml (Step: 0.1 Ml)
Maximum Accumulated Volume: 9999.9 Ml (Step: 0.1 Ml)
Time Range: 1 Min~9999 Min (Step: 1 Min)
Power Supply: AC 85~265V, 50/60Hz
Trademark: Med Equipment
Specification: CE, ISO
Origin: Guangzhou, China
Model NO.: MED-OIP-900
Net Weight: 2.2kg
Pump Type: Drip Type Infusion Pump
Pumping Way: Peristalic Fingers
Adjustable Drop Rate Range: 1~400 Drops/Min (Step: 1 Drop/Min)
Purge Rate: 800 Ml/H
Infusion Volume Range: 1 Ml~9999.9 Ml (Step: 0.1 Ml)
Maximum Accumulated Volume: 9999.9 Ml (Step: 0.1 Ml)
Time Range: 1 Min~9999 Min (Step: 1 Min)
Power Supply: AC 85~265V, 50/60Hz
Trademark: Med Equipment
Specification: CE, ISO
Origin: Guangzhou, China
Infusion Pump
MED-OIP-900 

1. 4.3 inch color LCD with backlight
2. Three working modes: Rate/Volume/Time mode
3. Purge, KVO function
4. Heating and remote control functions
5. Audible and Visible alarms
6.Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle
7. Calibration function, suitable for any brand disposable IV set 
 
 
Size: 188 mm(L)*198 mm(W)*228 mm(H)
Net Weight: 2.2kg
 
 
Technical Specifications
 
Pump Type Drip type infusion pump
Pumping Way Peristalic fingers
Adjustable Drop Rate Range 1~400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range 1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)
Flow Precision Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set) 
Mechanical precision within±2%.
Purge Rate 800 ml/h
KVO Rate 1 ml/h (1~300 ml/h)

         3 ml/h (greater than 300 ml/h);
 
Infusion Volume Range: 1 ml~9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume:9999.9 ml (step: 0.1 ml)
Time Range:1 min~9999 min (step: 1 min)
Occlusion Alarm Threshold: High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa)
                           Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa)
                           Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)
Alarm:    Infusion Complete, Empty, Faulty Signal, Misoperation,
        Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Air Bubble Detector: Method: ultrasonic wave, sensitivity: >=25 μL
Fuse: F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity),
      2 pcs (installed inside pump).
Power Supply:  AC 85~265V, 50/60Hz;
Internal Battery:11.1V rechargeable li-ion battery. Capacity:>=2000mAh;
                 the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for
                 8 hours (Medium rate specified by GB 9706.27-2005).
Power: <=40VA
Size:  188 mm(L)*198 mm(W)*228 mm(H)
Weight: 2.2KG
Environment Requirements:  Transport
                           Ambient Temperature: -30ºC~+55ºC
                           Relative Humidity: 20%~95% (non-condensing)
                           Atmosphere Pressure: 70kPa~106kPa
                           Storage
                           Ambient Temperature: -30ºC~+55ºC
                           Relative Humidity: 20%~95%
                           Atmosphere Pressure: 70kPa~106kPa
                           Operation
                           Ambient Temperature: +5~+40ºC
                           Relative Humidity: 20%~90%
                           Atmosphere Pressure: 86kPa~106kPas
 
 
 
 
Calibration function, disposable IV set of any brand is suitable for this pump. Three working modes: Rate/Volume/Time mode.
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Purge, KVO function
 
Heating function , suitable for infusing in winter or there is requirement for the fluid medication temperature.
 
Remote Controller
makes operating more convenient.
 
infusion monitoring system (Optional),
the status of each pump is displayed in real time at the central station through wireless transmission.
 
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication
 
Drip Detector.
 
Infusion Stand (Optional)


Welcome to contact us for moe information of Good quality Infusion Pump in hot sales. Infusion Pump
MED-OIP-900 

1. 4.3 inch color LCD with backlight
2. Three working modes: Rate/Volume/Time mode
3. Purge, KVO function
4. Heating and remote control functions
5. Audible and Visible alarms
6.Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle
7. Calibration function, suitable for any brand disposable IV set 
 
 
Size: 188 mm(L)*198 mm(W)*228 mm(H)
Net Weight: 2.2kg
 
 
Technical Specifications
 
Pump Type Drip type infusion pump
Pumping Way Peristalic fingers
Adjustable Drop Rate Range 1~400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range 1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)
Flow Precision Within±3% (using the IV set appointed by the manufacturer or calibrated high quality IV set) 
Mechanical precision within±2%.
Purge Rate 800 ml/h
KVO Rate 1 ml/h (1~300 ml/h)

         3 ml/h (greater than 300 ml/h);
 
Infusion Volume Range: 1 ml~9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume:9999.9 ml (step: 0.1 ml)
Time Range:1 min~9999 min (step: 1 min)
Occlusion Alarm Threshold: High: 800 mmHg±200 mmHg (106.7kPa±26.7kPa)
                           Medium: 500 mmHg±100 mmHg (66.7kPa±13.3kPa)
                           Low: 300 mmHg±100 mmHg (40.7kPa±13.3kPa)
Alarm:    Infusion Complete, Empty, Faulty Signal, Misoperation,
        Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Air Bubble Detector: Method: ultrasonic wave, sensitivity: >=25 μL
Fuse: F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity),
      2 pcs (installed inside pump).
Power Supply:  AC 85~265V, 50/60Hz;
Internal Battery:11.1V rechargeable li-ion battery. Capacity:>=2000mAh;
                 the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for
                 8 hours (Medium rate specified by GB 9706.27-2005).
Power: <=40VA
Size:  188 mm(L)*198 mm(W)*228 mm(H)
Weight: 2.2KG
Environment Requirements:  Transport
                           Ambient Temperature: -30ºC~+55ºC
                           Relative Humidity: 20%~95% (non-condensing)
                           Atmosphere Pressure: 70kPa~106kPa
                           Storage
                           Ambient Temperature: -30ºC~+55ºC
                           Relative Humidity: 20%~95%
                           Atmosphere Pressure: 70kPa~106kPa
                           Operation
                           Ambient Temperature: +5~+40ºC
                           Relative Humidity: 20%~90%
                           Atmosphere Pressure: 86kPa~106kPas
 
 
 
 
Calibration function, disposable IV set of any brand is suitable for this pump. Three working modes: Rate/Volume/Time mode.
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
Purge, KVO function
 
Heating function , suitable for infusing in winter or there is requirement for the fluid medication temperature.
 
Remote Controller
makes operating more convenient.
 
infusion monitoring system (Optional),
the status of each pump is displayed in real time at the central station through wireless transmission.
 
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions.
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication
 
Drip Detector.
 
Infusion Stand (Optional)


Welcome to contact us for moe information of Good quality Infusion Pump in hot sales.

Pain Relief Patch(Pain Areas)

Pain Relief Patch
[Name] Medical Cold Patch
[Package Dimension] 6cm×8cm 4pieces/box
The pain relief patch is composed of three layers, namely, backing lining, middle gel and protective film. It is free from pharmacological, immunological or metabolic ingredients.
[Scope of Application]
For cold physiotherapy, closed soft tissue only.
[Indications]
The patches give fast acting pain relief for strains, sprains, cramp, bruises, swollen areas or joint stiffness.
[How To Use a Patch]
Please follow the Schematic Diagram. One piece, one time.
The curing effect of each piece can last for 6-8 hours.
[Attention]
Do not apply the patch on the problematic skin, such as wounds, eczema, dermatitis,or in the eyes. People allergic to herbs and the pregnant are advised not to use the medication. If swelling or irritation occurs, please stop using and if any of these effects persist or worsen.notify your doctor or pharmacist promptly. Children using the patch must be supervised by adults.
[Storage Conditions]
Store below 30c in a dry place away from heat and direct sunlight.







Pain Relief Patch(Pain Areas),Shouler Pain Relief Patch,Joints Pain Relief Patch, Muscle Pain Relief Patch

Shandong XiJieYiTong International Trade Co.,Ltd. , https://www.xjytmedical.com

Posted on