Noiseless Dental Amalgamator for Mixing Amalgam Capsules

Model NO.: Dental Amalgamator
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: Ysyjxz20122550683
Absorbed Power 200 W: Noise:65dB
Dimensions: 33 X27 X 20 Cm
Trademark: SPTA
Transport Package: 1piece in 1 Box
Specification: CE
Origin: China
HS Code: 9018499000
Feature:

1.This kind of amalgamator, controlled by a microprocessor, ensures a precise, controlled, consistent mix.
2.With the width of the oscillating range, the mixing frequency, and your selected time(1-99S).
3.It's revolve according to "8" model.
4.For mercury-based fillings. trust the performance of DB338 amalgamator. Together, it provides the clinical perfection you need with the ease-of-use you want.
5.For safe operation, the DB338 deactivates when you open the front cover to access the capsule.
6.Its ergonomic design is easy to use, stable, extremely quiet and easy to clean and maintain


Technical:

Voltage 220V/50Hz(110V/60Hz are available)
Absorbed power 200 W
Fuse 2A
Mixing frequency 4500 tr/mn(cpm)
Functioning intermittent
Programmable mixing time 1-99 sec
Dimensions 33x27x20 CM
NET weight 4.3Kg
Noise: 65dB.

Welcome to contact us via Whatsapp or E-mail:

+86-13790746067

 
 

Non-Inactivated Disposable Virus Sampling Tube

This disposable Non-Inactivated virus sampling tube is an upgrade from the Hank's solution. Additional various components, such as BSA, HEPES, amino acids, cryoprotectant, etc., are added to enhance the virus integrity. It can be used for nucleic acid extraction of virus, mvcoplasma chlamydia and ureaplasma samples and later virus isolation.
This disposable non-inactivated virus sampling tube consists of fibrous swab and culture medium.The medium contains antibiotics and antimycotics for the purpose of inhabitation of bacteria and veasts overgrowth. It helps to maintain the cellular integrity and preserve the viruses, mycoplasma, chlamydiae and ureaplasma.
When collect specimens with this disposable Non-inactivated virus sampling tube, tube can be transported to the laboratory at 2-8ºC within 2 days. If it can not be delivered to the laboratory within 48hours, it should be stored at-70ºC or below, and ensure that the collected specimens are delivered to the laboratory within 1 week. Avoid repeated freeze-thaw cycles. For best performance, complete testing within 24 hours.

Nucleic acid extraction tube,DNA virus sampling tube,Viral Transport Medium Test Tube,Non-Inactivated VTM,Non-Inactivated specimen tube

Shenzhen Uni-medica Technology Co.,Ltd , https://www.nbunimed-global.com

Posted on